ISO 9001:2008
Prefabricados Alberdiwww.prefabricadosalberdi.com

Reinforced concrete piping

DESCRIPTION AND USES

Reinforced pipingThe HM reinforced concrete pipes by PREFABRICADOS ALBERDI S.A. is intended, principally, for underground pipelines, road drainage, black water or sanitation, rainwater and surface water by gravity or, occasionally, pressurised. Given their inner steel reinforcement, they are ideal for bearing considerable loads generated by road traffic or significant coverings of soil.

They can be classified according to their geometric shape and their manufacturing method. On one hand, there are the “bell and spigot” type pipes manufactured by radial compression (hereafter TEC) and “tongue and groove” or “halved joint” type pipes made by vibrocompression (hereafter TEM).

At the same time, the European Directive 89/106/CE of Royal Decree 1630/1192 establishes that reinforced concrete pipes must have the CE marking complying with the provisions of the current standard in force, UNE EN 1916:2003. This is why at PREFABRICADOS ALBERDI S.A. we mark all our pipes accordingly. 

 

TECHNICAL DATA

 

NAME AND REGULATIONS: REINFORCED CONCRETE PIPES

RESISTANCE CLASS
Ff: Cracking load (KN/m2)
Fn: Breaking load (KN/m2)

ACCORDING TO UNE EN 1916

  CLASS 60 CLASS 90 CLASS 135 CLASS 180
Ff 40 60 90 120
Fn 60 90 135 180

ACCORDING TO ASTM C76 M

  CLASS I CLASS II CLASS III CLASS IV CLASS V
Ff 40 50 65 100 140
Fn 60 75 100 150 175

 

Reinforced piping by radial compression

TEC PIPE

TEC PIPE

DN
(mm)
DE
(mm)
E
(mm)
LU
(mm)
WEIGHT
(kg/ml)
300 540 55 2,400 175
400 680 62.5 2,400 271
500 780 70 2,400 355
600 910 76.5 2,400 492
700 1,040 85 2,400 585
800 1,150 95 2,400 727
1,000 1,405 110 2,400 1,055
1,200 1,675 125 2,400 1,460
1,400 1,900 145 2,400 1,840
1,500 1,900 150 2,400 2,050
1,600 2,240 160 2,400 2,640
1,800 2,295 180 2,400 2,845

 

Reinforced piping by vibrocompression

TEM PIPE

TEM PIPE

DN
(mm)
DE
(mm)
E
(mm)
LU
(mm)
WEIGHT
(kg/ml)
1,600 1,940 170 2,400 175
1,800 2,180 190 2,400 3,010
2,000 2,400 200 2,400 3,350
2,500 3,000 250 2,400 5,250
3,000 3,600 300 2,400 7,775

 

QUALITY CONTROL

  • Tightness test using the air leakage test on 100% of the pipes manufactured the previous day (up to Ø1200 included).
  • If the pipes are manufactured in batches for a particular client order (subject to a surcharge), in addition to the aforementioned test, the following quality control will be performed:
    • Compression resistance of specimens of fresh concrete
    • Analysis of the consistency of fresh concrete
    • Alkalinity and water absorption
    • Layout of the reinforcement
    • Mechanical resistance: breakage test of the three edges
    • Hydrostatic tests (up to Ø1200 included).
    • Tightness tests on the gasket

 

PHOTO GALLERY

 

 

Reinforced pipes in trenches on site 07
Reinforced pipes in trenches on site 04
Reinforced pipes in trenches on site 03
Reinforced pipes in trenches on site 08
 
Reinforced pipes in trenches on site 07
Reinforced pipes in trenches on site 06
Reinforced pipes in trenches on site 08
Reinforced piping
 
Reinforced piping
Reinforced piping
Reinforced piping
Reinforced piping
 
Reinforced piping
Reinforced piping
Reinforced piping
Reinforced piping
 
Reinforced piping
Reinforced piping
Reinforced concrete piping
Reinforced concrete piping
 


We use our own and third party cookies, for the analysis of user navigation. If you continue browsing, we consider that you accept the use.
You can change the settings or get more information here.